img
img
Radiation doses to technologists working with 18F FDG in a PET center with high patient capacity      
Yazarlar (8)
Mustafa Demir
İstanbul Üniversitesi-Cerrahpaşa, Türkiye
Bayram Demir
İstanbul Üniversitesi, Türkiye
Doğan Yaşar
Kırşehir Ahi Evran Üniversitesi, Türkiye
Haluk B. Sayman
Metin Halaç
Türkiye
Asm Sabbir Ahmed
Kazım Özcan
İlhami Uslu
Türkiye
Devamını Göster
Özet
The increasing numbers of PET studies for routine diagnosis creates a real hazard to radiation workers. The aim of this study is to estimate the annual whole-body and finger radiation dose to technologists working with (18)F-FDG in a PET center with high patient potential. In our PET center, the number of PET imaging has increased almost to 5000 studies per year. Our standard dose for tumor imaging is 518 MBq of (18)F-FDG. Five technologists performing all steps of (18)F-FDG imaging (5 patients per technologist in a day) were officially involved round the week for handling and injecting (18)F-FDG to patients. Whole-body and finger dose measurements with TLDs were performed for two different time periods: i) before shielding precautions during the first 6 months (without a shielding for sterile syringe and without a lead container for shielded syringe) and ii) after shielding precautions during the next 6 months (with a shielding for sterile syringe and with a lead container for shielded syringe). The average annual whole-body radiation dose for one technologist before shielding precautions was 7.82 mSv and after shielding precautions was 5.76 mSv. On the other hand, while the average annual finger radiation doses for one technologist before shielding precautions were 210.36 and 293.72 mSv for the left and right hand, after shielding precautions were they 158.16 and 217.58 mSv for the left and right hand, respectively. According to our results, if one technologist performs the whole-body PET imaging of 5 patients per day, the annual radiation dose to this technologist will not exceed the recommended limits by ICRP.
Anahtar Kelimeler
whole-body dose | finger doses | personnel dosimetry | (18)F-FDG | PET/CT
Makale Türü Özgün Makale
Makale Alt Türü SSCI, AHCI, SCI, SCI-Exp dergilerinde yayımlanan tam makale
Dergi Adı NUKLEONIKA
Dergi ISSN bbb
Dergi Tarandığı Indeksler SCI-Expanded
Dergi Grubu Q4
Makale Dili İngilizce
Basım Tarihi 01-2010
Cilt No 55
Sayı 1
Sayfalar 107 / 112
Makale Linki https://www.researchgate.net/publication/242542123_Radiation_doses_to_technologists_working_with_18_F-FDG_in_a_PET_center_with_high_patient_capacity
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
WoS 21
Google Scholar 46

Paylaş