img
Intra- and inter-rater reproducibility of the face-to-face and tele-assessment of timed-up and go and 5-times sit-to-stand tests in patients with chronic obstructive pulmonary disease        
Yazarlar
İsmail Özsoy
Selçuk Üniversitesi, Türkiye
Dr. Öğr. Üyesi Muhammed İhsan KODAK Dr. Öğr. Üyesi Muhammed İhsan KODAK
Kırşehir Ahi Evran Üniversitesi, Türkiye
Dr. Öğr. Üyesi Caner KARARTI Dr. Öğr. Üyesi Caner KARARTI
Kırşehir Ahi Evran Üniversitesi, Türkiye
Gülşah Özsoy
Selçuk Üniversitesi, Türkiye
Arzu Ertürk
Türkiye
Turhan Kahraman
Türkiye
Özet
Timed-Up and Go (TUG) and 5-Times Sit-to-Stand (5STS) are frequently used in clinical practice for patients with chronic obstructive pulmonary disease (COPD). The aim of the study was to investigate the intra- and inter-rater reproducibility of the TUG and 5STS as both face-to-face and tele-assessment tests in patients with COPD. Forty-four patients with diagnosed COPD were included. Evaluations were carried out face-to-face and tele-assessment (synchronized and asynchronized). Inter-reliability between face-to-face and tele-assessment was excellent for TUG (ICC = 0.977) and 5STS (ICC = 0.970). Inter-reliability between two tele-raters was also excellent for TUG (ICC = 0.995) with the SEM = 0.04, SEM95% = 0.08, and SDC95% = 0.10 s, and 5STS (ICC = 0.990) with the SEM = 0.06, SEM95% = 0.12, and SDC95% = 0.18 s. Intra-rater reliability of the tele-assessment (synchronized) was excellent for TUG (ICC = 0.976) and 5STS (ICC = 0.964). The SEM, SEM95%, and SDC95% values were computed as 0.08, 0.16, and 0.22 s for TUG, and 0.11, 0.22, and 0.31 s for 5STS, respectively. The TUG and 5STS tests are reproducible tele-assessment measures in patients with COPD with excellent intra- and inter-rater reproducibility. The authors recommend these tests as practical assessment tools in patients with COPD at home for tele-health interventions. The reported SEM, SEM95%, and SDC95% values can be used as a minimum change that needs to be observed to be confident that the observed change is real and not, potentially, a product of measurement error.
Anahtar Kelimeler
Tele-assessment | chronic obstructive pulmonary disease | timed-up and go test | 5-times sit-to-stand test | reliability
Makale Türü Özgün Makale
Makale Alt Türü SSCI, AHCI, SCI, SCI-Exp dergilerinde yayımlanan tam makale
Dergi Adı COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE
Dergi ISSN 1541-2555
Dergi Tarandığı Indeksler SCI-Expanded
Dergi Grubu Q4
Makale Dili Türkçe
Basım Tarihi 12-2022
Cilt No 19
Sayı 1
Sayfalar 125 / 132
Doi Numarası 10.1080/15412555.2022.2038119