Yazarlar (1) |
![]() Kırşehir Ahi Evran Üniversitesi, Türkiye |
Özet |
This study explores the effects of fin cross-sectional geometry on the thermal and hydraulic performance of a pin fin heat sink under turbulent flow conditions. The heat sink design features a base plate measuring 100 mm wide, 100 mm long and 3 mm high with 14 fins arranged in a 4-3-4-3 configuration, utilizing air as the working fluid. The investigation employs CFD simulations to analyze variations in heat sink performance due to different fin geometries, including circular and elliptical cross-sections with and without perforations. Results indicate that elliptical fins, particularly those with a radius ratio of 0.50, significantly enhance heat transfer rates, achieving improvements in the HTPF of up to 90% compared to traditional circular designs. The study highlights a clear correlation between increasing Re and the Nu, demonstrating the effectiveness of elliptical fins in turbulent flow conditions. However, while perforated ... |
Anahtar Kelimeler |
Makale Türü | Özgün Makale |
Makale Alt Türü | SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale |
Dergi Adı | Case Studies in Thermal Engineering |
Dergi ISSN | 2214-157X Wos Dergi Scopus Dergi |
Dergi Tarandığı Indeksler | SCI-Expanded |
Dergi Grubu | Q1 |
Makale Dili | İngilizce |
Basım Tarihi | 08-2025 |
Cilt No | 74 |
Sayı | 106918 |
Doi Numarası | 10.1016/j.csite.2025.106918 |
Makale Linki | https://doi.org/10.1016/j.csite.2025.106918 |