img
img
Upgrade of the TAMU MDM-focal plane detector with MicroMegas technology    
Yazarlar (10)
A Spiridon
E Pollacco
Bt Roeder
A Saastamoinen
R Chyzh
Dr. Öğr. Üyesi Murat DAĞ Dr. Öğr. Üyesi Murat DAĞ
Türkiye
Re Tribble
L Trache
G Pascovici
De Oliveira R
Devamını Göster
Özet
A gridded ionization chamber used as a focal plane detector at the back of the TAMU-MDM spectrometer was modified to use MicroMegas technology for the purpose of improving energy resolution and particle identification. The upgraded system was tested in experimental conditions with several heavy-ion beams at 12 MeV/u and found to achieve resolutions between 3.2% and 4.8%. This is a significant improvement over the previous performance of 10–15% obtained using the existing, conventional ionization chambers.
Anahtar Kelimeler
Makale Türü Özgün Makale
Makale Alt Türü SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale
Dergi Adı Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Dergi ISSN 0168-583X Wos Dergi Scopus Dergi
Dergi Tarandığı Indeksler SCI
Makale Dili İngilizce
Basım Tarihi 06-2016
Cilt No 376
Sayfalar 364 / 368
Doi Numarası 10.1016/j.nimb.2016.02.011
Makale Linki http://linkinghub.elsevier.com/retrieve/pii/S0168583X16001282
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
Google Scholar 9
Upgrade of the TAMU MDM-focal plane detector with MicroMegas technology

Paylaş