Automatic MTPA Control for IPMSM Drives Based on Pseudorandomly Reversed Fixed-Frequency Sinusoidal Signal Injection   
Yazarlar
Tianfu Sun
Ke Li
Jianing Liang
Doç. Dr. Mikail KOÇ
Türkiye
Yimin Zhou
Özet
Signal-injection-based methods are a kind of competitive maximum torque per ampere (MTPA) control schemes for interior permanent magnet synchronous motor drives, due to their motor parameter independence and satisfactory control performance. However, the high current spectrum peaks (CSPs) produced by the conventional fixed-frequency injected signals may cause negative effects. To deal with this problem, an MTPA control method based on pseudorandomly reversed fixed-frequency (PRRFF) sinusoidal signal injection is proposed in this article. The PRRFF sinusoidal signals are injected into the d-axis currents via a specific current loop, and the MTPA operating points can be detected utilizing the resultant system response. Benefiting from the random characteristic of the injected signals, the proposed method can achieve far lower injection-induced CSPs than the conventional fixed-frequency injection methods. Moreover, benefiting from the fixed-frequency characteristic of the injected signals, the proposed method avoids the difficult matching of candidate injection frequencies that exists in the pseudorandom-frequency injection method. The validity of the proposed method is confirmed by experiments.
Anahtar Kelimeler
Current spectrum peaks (CSPS), interior permanent magnet synchronous motor (IPMSM) drives, maximum torque per ampere (MTPA) control, motor parameter variations, signal injection.
Makale Türü Özgün Makale
Makale Alt Türü SSCI, AHCI, SCI, SCI-Exp dergilerinde yayımlanan tam makale
Dergi Adı IEEE Transactions on Industrial Electronics
Dergi ISSN 0278-0046
Dergi Tarandığı Indeksler SCI-Expanded
Dergi Grubu Q1
Makale Dili İngilizce
Basım Tarihi 07-2023
Doi Numarası 10.1109/TIE.2023.3301523
Makale Linki https://doi.org/10.1109/TIE.2023.3301523