Yazarlar |
Sabit Numan Kuyubaşı
Türkiye |
Arif Gök
Kütahya Dumlupınar Üniversitesi, Türkiye |
Sermet İnal
Türkiye |
Prof. Dr. Levent URTEKİN
Kırşehir Ahi Evran Üniversitesi, Türkiye |
Alaaddin Oktar Üzümcügil
Türkiye |
Cengizhan Kurt
Türkiye |
Ali İhsan Kılıç
Türkiye |
Kadir Gök
İzmir Bakırçay Üniversitesi, Türkiye |
Özet |
In this study, the biomechanical behavior of three different screw materials (Ti6Al4V, Magnesium AZ91 and Ti6Al4V-HA) was analyzed to fix the femoral neck fracture with triangular fixation under axial loading and it was investigated which material was better biomechanically. Geomagic Studio and SolidWorks software were used for three-dimensional (3D) process. The triangle configuration was preferred for femoral neck fracture. The computer-aided numerical analyses were carried out in AnsysWorkbench for two different materials. We believe that the fixation materials investigated may have a role in taking patients away from recurrent anesthesia and orthopaedic surgical risks. |
Anahtar Kelimeler |
biomechanics | Femoral neck fracture | finite element analysis | magnesium screw |
Makale Türü | Özgün Makale |
Makale Alt Türü | SSCI, AHCI, SCI, SCI-Exp dergilerinde yayımlanan tam makale |
Dergi Adı | Journal of Mechanics in Medicine and Biology |
Dergi ISSN | 0219-5194 |
Dergi Tarandığı Indeksler | SCI-Expanded |
Dergi Grubu | Q4 |
Makale Dili | Türkçe |
Basım Tarihi | 01-2023 |
Cilt No | 11 |
Sayı | 1 |
Sayfalar | 100 / 115 |
Doi Numarası | 10.1142/S0219519423500495 |
Makale Linki | https://www.worldscientific.com/doi/abs/10.1142/S0219519423500495?journalCode=jmmb |